Walls
|
"Enjoy a pleasant indoor climate" |
Wrap up well to feel comfortable Find protection from the cold ,heat and the noise of the outside world, while still leaving room for creativity. This means a truly insulated wall, but still with a modern face. Architecture for people. Isover - for more comfort and efficiency |
|
External thermal insulation compound system with Isover stone wool facade boards (e.g. Sillatherm WVP 1) U = 0,20 W/m²K 3321 The kinds of fixing (with adhesive and/or plug anchor) must be in compliance with the application standards (European technical approvals) for external thermal insulation compound systems. The type of fixing is depending on the building height, exposure (wind load) and static conditions. | |
|
External thermal insulation compound system with Isover stone wool lamella facade boards (e.g. Sillatherm WVL) Rw = 53 dB 3322 The kinds of fixing (with adhesive and/or plug anchor) must be in compliance with the application standards (European technical approvals) for external thermal insulation compound systems. The type of fixing is depending on the building height, exposure (wind load) and static conditions. The Sillatherm WVL system has a particulary high mechanic performance such as tensil strength perpendicular to the faces and can be applied on buildings up to a height of 20 m without plugging and anchoring in most of european countries. This does not apply for surfaces with reduced interface strength such as old renderings, concrete surfaces with rests of formwork oil and around edges. | |
|
External thermal insulation compound system with Isover compact facade board U = 0,21 W/m²K 3323 0,2 leveling layer The kinds of fixing (with adhesive and/or plug anchor) must be in compliance with the application standards (European technical approvals) for external thermal insulation compound systems. The type of fixing is depending on the building height, exposure (wind load) and static conditions. | |
|
Double-leaf cavity wall with full-cavity insulation Rw = 64 dB 3325 cm Composition | |
|
Ventilated outer wall with reinforced cement facade-cladding U = 0,19 W/m²K 3326 cm Composition | |
|
Ventilated outer wall with exterior facade cladding (board) Rw = 45 dB 3327 2,4 Ventilation space | |
|
Ventilated outer wall with glass facade U = 0,24 W/m²K 3328 faced with glass tissue 2,5 Ventilation area | |
|
Ventilated outer wall with precast concrete blocks U = 0,23 W/m²K 3329 8,0 Isover facade insulation board 2,0 Ventilation area | |
|
Outer wall with framework boarding Rw = 53 dB 33210 2,4 Framework boarding
| |
|
Timber framework wall with composite heat insulation system consisting of Sillatherm HD plaster baseboards Rw = 55 dB 33211 Difunorm Varion vapour barrier 1,6 Chipboard board 0,5 Leveling layer with textil reinforced compound layer with undercoat 0,4 Thin layer of external rendering | |
|
Timber framework wall with timber boarding Rw = 45 dB 33212 16,0 Isover lightweight glass wool between rafters 2,4 Framework boarding | |
|
Timber framework wall with timber Rw = 45 dB 33213 1,2 Chipboard board 16,0 Isover lightweight glass wool 1,6 Chipboard board | |
Interior Thermal Insulation
|
Interior insulation of a woodblock wall Rw = 45 dB 33214 12,0 Isover lightweight glass wool 10,0 Woodblock wall | |
|
Interior insulation of an outer wall with resilient bars ÄRw =10 dB 33215 10,0 Isover lightweight glass wool 1,5 Internal rendering
| |
|
Interior insulation of an outer wall with metal studs and beams ÄRw = 10 dB 33216 10,0 Isover lightweight glass wool 1,0 Air space
| |
|
Interior insulation of an outer wall with Isover composite boards ÄRw = 8 dB 33217 0,5 Glue fixing
| |