Fire Rated Insulation
Insulation classified A1 or A2, s1-d0 according to the Euroclass system, can reduce the risk of fuelling a fire
Euroclass A1 and Euroclass A2-s1,d0
The European Reaction to Fire Classification of construction products and building elements (EN 13501-1:2018), or Euroclass system is widely used across Europe and the UK to evaluate the reaction to fire of construction products and building materials. Materials tested using this system can be classified from A1 to E based on how they behave when exposed to fire . There is also F Class – materials classified as F are either untested or do not meet the criteria.
Euroclass A1 is used for materials that are non-combustible. This means they will not contribute to development or fire spread in any significant way – and they will not ignite, produce flames, smoke, or flaming droplets when exposed to fire. Many Isover glass mineral wool products, such as Isover Acoustic Partition Roll, Isover Spacesaver Loft Insulation, Isover Cavity Wall Slab, and Isover Timber Frame Insulation achieve Euroclass A1 reaction‑to‑fire classification
Euroclass A2-s1, d0 materials are classified as having very limited contribution if exposed to fire. Euroclass A2-s1, d0 products will also be assessed for additional criteria, such as the likelihood for smoke production (s1-3) or any character change (d0-d2), when exposed to fire. There are three smoke intensity levels s1 - s3 with s3 being the worst, and three classes for character changes such as the tendency to produce burning droplets, particles,. d0 - d2 with d2 being the worst. The additional criteria for a product to produce smoke and flaming droplets or particles is valid for products rated Euroclass A2 - D. Isover offers a range of Euroclass A2-rated insulation products suitable for various applications such as Isover Climcover Roll Alu2.
The benefits of non-combustible insulation
Being non-combustible, mineral wool can help reduce the risk of contributing to a fire or increasing the fire load. Let’s look at more benefits and related products.
Many glass and stone mineral wool products are rated A1 in the Euroclass Reaction to Fire Classification System. This means that they do not contribute to a fire and they do not emit any smoke or flaming droplets .
Isover products are tested in accordance with BS EN 13501-1:2018 and CE & UKCA marked for their specific applications and intended use
Understanding ‘reaction to fire’ and ‘fire resistance’
There are two key provisions often discussed in relation to insulation and fire safety:
- Reaction to fire
- Fire resistance.
It’s important to understand the difference between these two descriptions when specifying products for fire safety applications.
Reaction to fire evaluates how a material contributes to fire development and spread. A product's performance is critical in the early stages of a fire.
Fire resistance measures the ability of a complete system to resist fire penetration and maintain performance over a defined period. Fire resistance becomes essential once a fire is established, by helping to contain its spread.
Learn more about fire resistant insulation
Get to know fire-rated insulation better with these articles written by our development teams and insulation specialists.
Isover fire-rated insulation products
Mineral wool insulation products can contribute to the fire resistance performance of a system , for example when used in various British Gypsum GypWall systems . The following selection from Isover includes products that have been tested and classified under relevant acoustic and thermal performance.
Isover ULTIMATE™ industrial fire insulation products
Designed to be used in demanding industrial applications, ULTIMATE™ slabs and wired mats are next-generation mineral wool products tested to the relevant British and European fire resistance standards and offer up to two hours of fire protection.
Frequently Asked Questions
Can I return an Isover product?
For all our Isover product and delivery information, please read our product and delivery guide here or contact our Customer Service Team:
I cannot find a product I used to buy.
Please contact our Technical Support Team, who are here to help you with the products we have available for all your needs.
Contact details
Opening hours: Monday – Friday 08:30 – 16:30
Telephone: 0115 969 8302
Email: [email protected]
I can’t find an Environmental Product Declaration (EPD) for a product on your website. Where can I find the information?
Please contact our Technical Support Team
Contact details
Opening hours: Monday – Friday 08:30 – 16:30
Telephone: 0115 969 8302
Email: [email protected]
Where is Isover manufactured?
The majority of Isover products are manufactured in the UK at our Runcorn site – with a selection of other products produced in Sweden, Poland, Netherlands and Germany.
Where can I find information on the density of your products?
We do not publish standalone density information, however all Runcorn manufactured products do have their density published in their Environmental Product Declarations. You can find a list of them here. If you require any more information or assistance, please contact our Technical Support Team